Medical Device Lab
KT88-3200 Digital Brain Electric Activity Mapping
MDL

KT88-3200 Digital Brain Electric Activity Mapping

- KT88-3200 Digital Brain Electric Activity Mapping system collects EEG signals for detecting epilepsy, brain tumors, and more
- Features 10/20 electrodes placement with adjustable leads for sampling
- Offers continuous 24-hour brainwave recording and automatic calibration
- Provides powerful playback function with adjustable amplitudes and display speeds
- Offers digital filter system with customizable settings
- Includes EEG signal clipping function for analyzing and storing waveform segments
- Features powerful automatic analysis for power spectrum and pathologic wave detection
- Provides case management function with easy data export/import and integrative report editing

SKU
MDL-FACC1FD2F3
Brand
MDL
Manufactured by
MedicalDeviceLab
Availability
In stock
  • Worldwide shipping
Share
Clinical & Diagnostic Devices

KT88-3200 Digital Brain Electric Activity Mapping

Comprehensive EEG signal acquisition and analysis system with integrated amplification, real-time processing, and advanced diagnostic capabilities. Supports international 10/20 electrode placement standards with continuous recording up to 24 hours and powerful automated analysis for epilepsy, intracranial inflammation, cerebrovascular disease, and brain tumor detection.

Indication(s): Epilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors
Range / sizes: Standard 10/20 electrode system with configurable lead combinations
Sterilisation: As applicable
2 Year Warranty Lifetime Support Fast Delivery USB Interface
Ordering Ref.
74c69a6053b9
ConfigurationStandard 10/20 System
MaterialMedical-grade electrodes & bioamplifier
ApplicationNeurological diagnostics
Optional video recording and SpO2 monitoring available. Customizable lead configurations and analysis parameters to meet institutional requirements.

Clinical overview

The KT88-3200 is a professional-grade digital electroencephalography system designed for comprehensive brain electrical activity mapping and analysis. It collects EEG signals via electrodes and processes them through integrated bioelectric amplification and analog-to-digital transformation to generate high-fidelity electroencephalograms with color-depth visualization. The system is applicable for diagnosing epilepsy, intracranial inflammation, cerebrovascular diseases, and brain tumors, making it an essential tool for neurology departments, epilepsy centers, and comprehensive diagnostic facilities.

With continuous recording capability up to 24 hours, automatic calibration, and powerful playback features, the KT88-3200 enables clinicians to capture extended monitoring sessions and perform detailed retrospective analysis. The system supports international 10/20 electrode placement standards with flexible lead configuration during both acquisition and replay, accommodating diverse clinical protocols and patient populations.

Key features & surgeon benefits

Signal Acquisition

Superior EEG Capture

  • International 10/20 electrode placement standard with flexible lead reconfiguration
  • Bioelectric amplifier with integrated A/D transformation for accurate signal fidelity
  • Continuous recording up to 24 hours with automatic full-system calibration
Analysis & Visualization

Advanced Diagnostic Tools

  • Powerful playback with adjustable amplitude and display speed for detailed waveform review
  • Digital filter system with customizable window types for signal optimization
  • Electronic frequency ruler and partial enlargement window for precise measurements
Automated Processing

Intelligent Detection

  • Automatic power spectrum analysis and pathologic wave detection
  • EEG signal clipping and multi-segment parameter extraction
  • Event marking with color coding for rapid waveform retrieval by clinical event
Data Management

Comprehensive Documentation

  • Export/import functions with EDF and BDF format support for data exchange
  • Optional USB video recording with synchronized waveform and visual documentation
  • Professional isolation transformer with dual power supply and optoelectronic transmission for safety

Technical specifications

IndicationsEpilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors
Electrode SystemInternational 10/20 standard with configurable lead combinations
Recording DurationContinuous up to 24 hours
AmplificationIntegrated bioelectric amplifier with automatic calibration
Data TransmissionUSB interface with optoelectronic isolation
File FormatsEDF, BDF, proprietary formats with export/import capability
Optional FeaturesUSB video recording, SpO2 monitoring, multifunctional flash stimulator
Warranty2 Year Manufacturer Warranty

Standard instrument composition

ItemDescriptionQty
Main EEG UnitKT88-3200 Digital Brain Electric Activity Mapping System with integrated amplifier and processor1
Electrode SetComplete 10/20 standard electrode placement system with leads1
Bioamplifier ModuleIntegrated signal amplification and A/D conversion unit1
Calibration SystemAutomatic full-system calibration module1
USB Interface CableData transmission and power isolation cable1
Flash StimulatorMultifunctional USB-interface stimulator with manual/automatic control1
Software SuiteComprehensive EEG acquisition, analysis, and reporting software1

Get in touch for pricing & availability

Contact our clinical specialists to discuss system configuration, pricing, and delivery options for the KT88-3200. We provide comprehensive support and customization to meet your facility's diagnostic requirements.

Phone: (424) 270-9077
Email: [email protected]

Available on request

Configuration, paperwork & clinical fit

The full spec + documentation pack for this device ships ahead of purchase on request. A sales engineer responds within one business day.

Configuration sheet

Specifications, accessories & clinical fit

Sizes and dimensions, material and finish, compatible instruments and screw references, what ships in the set, lead time and warranty — all in one specification sheet, sent within one business day.

Documents & downloads

Regulatory paperwork & manuals

This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.

Get in touch

Need configuration help, certificates, or volume pricing?

Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.

Customer reviews

No reviews yet — be the first to share your experience.

Write a review

Your rating *

Related products

See all →
CMS4100 16 Channel Ambulatory Dynamic EEG Machine Portable17%
Contec

CMS4100 16 Channel Ambulatory Dynamic EEG Machine Portable

- Portable 16 channel ambulatory EEG machine - Continuous recording for up to 24 hours - Bluetooth sync sampling for real-time data uploading - Waveform playback with adjustable amplitude and speed - Case contrasting feature for waveform comparison - Spike-sharp wave auto-analysis system - Multifunctional digital filter system

$2,390.00
$1,990.00
In stock
KT88-2400 Digital Brain Electric Activity Mapping
MDL

KT88-2400 Digital Brain Electric Activity Mapping

- KT88-2400 Digital Brain Electric Activity Mapping is a cutting-edge device designed for collecting EEG signals - It is equipped with powerful playback and analysis functions for accurate diagnosis - Features bioelectricity amplifier for distilling brainwaves with up to 24 hours of continuous recording time - Offers digital filter system, EEG signal clipping function, and electronic frequency ruler for precise measurements - Includes multifunctional flash stimulator, perfect case management function, and integrative image and character report - Provides optional SpO2 function and video function for comprehensive data analysis and recording - Professional isolation transformer and dual power supply system ensure data security and accuracy.

$1,595.00
In stock
KT88 Digital Brain Electric Activity Mapping
MDL

KT88 Digital Brain Electric Activity Mapping

- 16 channels of EEG+2 channels of ECG (ECG is optional) - Sampling rate: 100 dots/s - Accuracy: 12bit - Input impedance: ≥10MΩ - Noise level: ≤5µVp-p - Magnification multiple: 10000 - Filter constant: all digital and free enactment

$1,295.00
In stock
Medical Enteral Feeding Pump with Optional Liquid Warmer MDLIS2922%
MDL

Medical Enteral Feeding Pump with Optional Liquid Warmer MDLIS29

4.3(3)

- The Medical Enteral Feeding Pump MDLIS29 is a reliable and accurate device for enteral feeding. - It offers a flow rate of 1-2000 ml/h in various increments for precise control. - The pump features alarms for occlusion, air-in-line, and other malfunctions to ensure patient safety. - With additional features like real-time infused volume and history log, monitoring and tracking are made easy. - Optional features include a liquid warmer with over-temperature alarm for patient comfort. - The pump can be powered by AC, battery, or even in a vehicle with a 12 V power supply. - Designed for safety, it has IPX5 fluid ingress protection and is classified as Class II, type CF.

$1,270.00
$995.00
In stock
Visible Spectrophotometer Machine MDLUV0831%
MDL

Visible Spectrophotometer Machine MDLUV08

- Single beam visible spectrophotometer ideal for routine analysis - Microprocessor controlled for easy operation - High resolution with 12000 line grating monochromator - Equipped with USB port for data output to PC - Compact design for easy portability - Four display modes for different measurements - Wavelength range: 325-1000nm - Spectral bandwidth: 4nm - Photometric accuracy: ±0.5%T

$1,290.00
$895.00
In stock
LCD Screen Uv Visible Spectrophotometer MDLUV0915%
MDL

LCD Screen Uv Visible Spectrophotometer MDLUV09

- LCD screen UV visible spectrophotometer model MDLUV09 - Equipped with a 2.5' LCD screen for clear display of standard curves and results - Can set up various standard curves for different solutions - Imported deuterium lamp for low stray light and accurate results - USB port for data output and connectivity to PC - Multiple results readout for wavelength, absorption, and transmittance - Automatic wavelength setting to avoid errors

$1,995.00
$1,695.00
In stock
Double Beam Uv Visible Spectrophotometer MDLUV1210%
MDL

Double Beam Uv Visible Spectrophotometer MDLUV12

- Wide screen double beam spectrophotometer MDLUV12 - Features long light path design for stability and accuracy - Powerful software functions for spectrum scanning, standard curve, kinetics, and more - Unique 520mm long light path design for improved resolution - Equipped with a 6 inches LCD display for easy viewing of results and curves - Calibration system for automatic calibration of baseline, wavelength, and dark current - USB port for data output and connection to a PC

$9,750.00
$8,770.00
In stock