
KT88-2400 Digital Brain Electric Activity Mapping
- KT88-2400 Digital Brain Electric Activity Mapping is a cutting-edge device designed for collecting EEG signals
- It is equipped with powerful playback and analysis functions for accurate diagnosis
- Features bioelectricity amplifier for distilling brainwaves with up to 24 hours of continuous recording time
- Offers digital filter system, EEG signal clipping function, and electronic frequency ruler for precise measurements
- Includes multifunctional flash stimulator, perfect case management function, and integrative image and character report
- Provides optional SpO2 function and video function for comprehensive data analysis and recording
- Professional isolation transformer and dual power supply system ensure data security and accuracy.
- SKU
- MDL-F8AED6F957
- Brand
- MDL
- Manufactured by
- MedicalDeviceLab
- Availability
- In stock
- ✓ Worldwide shipping
KT88-2400 Digital Brain Electric Activity Mapping
Advanced EEG system for comprehensive brain activity mapping and analysis. Supports international 10/20 electrode placement standards with continuous 24-hour recording capability, automated calibration, and powerful digital signal processing for accurate diagnosis of neurological conditions.
Clinical overview
The KT88-2400 Digital Brain Electric Activity Mapping system provides clinicians with a comprehensive platform for EEG signal acquisition, processing, and analysis. Using integrated bioelectricity amplification, analog-to-digital transformation, and advanced PC-based analysis, the system generates high-fidelity electroencephalograms with color-depth visualization. This enables rapid and accurate detection of pathological patterns associated with epilepsy, intracranial inflammation, cerebrovascular disease, and brain tumors.
The system combines international standard 10/20 electrode placement methodology with powerful digital signal processing, including FFT analysis, automatic power spectrum calculation, and pathologic wave detection. Continuous recording capability up to 24 hours with full-automatic calibration ensures reliable long-term monitoring for both routine clinical assessment and extended diagnostic protocols.
Key features & surgeon benefits
International Standard Electrode Placement
- 10/20 electrode placement method per international standards
- Configurable lead combinations during sampling and playback
- Bioelectricity amplifier for optimal signal distillation
Extended Monitoring with Advanced Visualization
- Continuous recording up to 24 hours with automatic calibration
- Adjustable amplitude and display speed for detailed waveform review
- Subdividing timeline divides one-second waveforms into 5 parts for precise analysis
Comprehensive Automated Analysis Tools
- Power spectrum analysis and pathologic wave detection
- Electronic frequency ruler for accurate period, amplitude, and frequency measurement
- Partial enlarging window for precise waveform examination
Intuitive Event Marking and Reporting
- Color-coded event marking for eyes open, eyes closed, and photic stimulation
- User-defined events with customizable waveform colors
- Integrative image and character reports editable in Word format
Technical specifications
| Indications | Epilepsy, intracranial inflammation, cerebrovascular diseases, brain tumors, neurological assessment |
|---|---|
| Electrode System | 10/20 international standard placement with configurable lead combinations |
| Recording Duration | Continuous up to 24 hours |
| Amplification | Integrated bioelectricity amplifier with full-automatic calibration |
| Signal Processing | A/D transformation, FFT analysis, digital filter system with customizable window types |
| Analysis Functions | Power spectrum analysis, pathologic wave detection, BEAM display, compressed spectrum, trend graphs |
| Data Interface | USB interface with optoelectronic data transmission; professional isolation transformer and dual power supply isolation |
| Optional Features | USB video camera for synchronized waveform and image recording; SpO2 monitoring function |
| Data Export | EDF and BDF format conversion for data exchange and further analysis |
| Warranty | 2 Year Manufacturer Warranty |
Standard system composition
| Component | Description | Qty |
|---|---|---|
| Main Unit | KT88-2400 Digital EEG Mapping System with integrated amplifier and processor | 1 |
| Electrode Set | 10/20 standard electrode placement system with leads | 1 |
| Bioelectricity Amplifier | Integrated signal amplification module | 1 |
| USB Interface Module | Data transmission and device connectivity | 1 |
| Flash Stimulator | Multifunctional USB-interface stimulator with manual and automatic control | 1 |
| Power Supply | Dual isolation system with professional isolation transformer | 1 |
| Software Suite | PC-based analysis, reporting, and case management software | 1 |
| Documentation | User manual, technical specifications, and training materials | 1 |
Get in touch for pricing & availability
Contact our sales team to discuss system configuration, pricing, and delivery options for the KT88-2400 Digital Brain Electric Activity Mapping system. We provide comprehensive support and customization to meet your clinical facility's specific requirements.
Email: [email protected]
Available on request
Configuration, paperwork & clinical fit
The full spec + documentation pack for this device ships ahead of purchase on request. A sales engineer responds within one business day.
Configuration sheet
Specifications, accessories & clinical fit
Sizes and dimensions, material and finish, compatible instruments and screw references, what ships in the set, lead time and warranty — all in one specification sheet, sent within one business day.
Documents & downloads
Regulatory paperwork & manuals
This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.
Get in touch
Need configuration help, certificates, or volume pricing?
Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.
Customer reviews
No reviews yet — be the first to share your experience.
Related products
See all →
CMS4100 16 Channel Ambulatory Dynamic EEG Machine Portable
- Portable 16 channel ambulatory EEG machine - Continuous recording for up to 24 hours - Bluetooth sync sampling for real-time data uploading - Waveform playback with adjustable amplitude and speed - Case contrasting feature for waveform comparison - Spike-sharp wave auto-analysis system - Multifunctional digital filter system

KT88-3200 Digital Brain Electric Activity Mapping
- KT88-3200 Digital Brain Electric Activity Mapping system collects EEG signals for detecting epilepsy, brain tumors, and more - Features 10/20 electrodes placement with adjustable leads for sampling - Offers continuous 24-hour brainwave recording and automatic calibration - Provides powerful playback function with adjustable amplitudes and display speeds - Offers digital filter system with customizable settings - Includes EEG signal clipping function for analyzing and storing waveform segments - Features powerful automatic analysis for power spectrum and pathologic wave detection - Provides case management function with easy data export/import and integrative report editing

KT88 Digital Brain Electric Activity Mapping
- 16 channels of EEG+2 channels of ECG (ECG is optional) - Sampling rate: 100 dots/s - Accuracy: 12bit - Input impedance: ≥10MΩ - Noise level: ≤5µVp-p - Magnification multiple: 10000 - Filter constant: all digital and free enactment

Medical Enteral Feeding Pump with Optional Liquid Warmer MDLIS29
- The Medical Enteral Feeding Pump MDLIS29 is a reliable and accurate device for enteral feeding. - It offers a flow rate of 1-2000 ml/h in various increments for precise control. - The pump features alarms for occlusion, air-in-line, and other malfunctions to ensure patient safety. - With additional features like real-time infused volume and history log, monitoring and tracking are made easy. - Optional features include a liquid warmer with over-temperature alarm for patient comfort. - The pump can be powered by AC, battery, or even in a vehicle with a 12 V power supply. - Designed for safety, it has IPX5 fluid ingress protection and is classified as Class II, type CF.

Visible Spectrophotometer Machine MDLUV08
- Single beam visible spectrophotometer ideal for routine analysis - Microprocessor controlled for easy operation - High resolution with 12000 line grating monochromator - Equipped with USB port for data output to PC - Compact design for easy portability - Four display modes for different measurements - Wavelength range: 325-1000nm - Spectral bandwidth: 4nm - Photometric accuracy: ±0.5%T

LCD Screen Uv Visible Spectrophotometer MDLUV09
- LCD screen UV visible spectrophotometer model MDLUV09 - Equipped with a 2.5' LCD screen for clear display of standard curves and results - Can set up various standard curves for different solutions - Imported deuterium lamp for low stray light and accurate results - USB port for data output and connectivity to PC - Multiple results readout for wavelength, absorption, and transmittance - Automatic wavelength setting to avoid errors

Double Beam Uv Visible Spectrophotometer MDLUV12
- Wide screen double beam spectrophotometer MDLUV12 - Features long light path design for stability and accuracy - Powerful software functions for spectrum scanning, standard curve, kinetics, and more - Unique 520mm long light path design for improved resolution - Equipped with a 6 inches LCD display for easy viewing of results and curves - Calibration system for automatic calibration of baseline, wavelength, and dark current - USB port for data output and connection to a PC












