Search

In Stock

Ventilator MSLVM11

– The Ventilator MSLVM11 is a versatile medical device designed to provide essential respiratory support.
– It offers a range of ventilation modes including SIPPV, IPV, IMV, SIMV, and SPONT for customized patient care.
– With a tidal volume range of 50 to 1200ml and maximum minute ventilation of ≥ 18 L/min, it ensures efficient respiratory therapy.
– The ventilator features adjustable I:E ratio, maximum safety pressure of ≤6.0 KPa, and PEEP range of 0.1 to 1.0kPa for precise control.
– It also includes functions like end-inspiratory plateau, sigh (deep breath), and duration of end expiration plateau for enhanced patient comfort.
– Equipped with a net weight of 15kg and compact dimensions of 390*320*310 (mm), the ventilator is portable and convenient to use.
– The MSLVM11 ventilator is a reliable choice for continuous operation, allowing for 24-hour usage on an AC utility main.

Original price was: $9,970.00.Current price is: $9,570.00.

SKU:MSLVM11

Specifications

1.1 Main Performances
1.1.1 Basic Functions
——End-inspiratory plateau;
——Sigh (deep breath);
1.1.2 Ventilation Modes
——SIPPV
——IPV
——IMV
——SIMV
——SPONT
1.2 Technical Data
—Tidal volume range: no less than 50 to 1200ml, permissible deviation: ±20 %.
——Maximum minute ventilation: ≥ 18 L/min, permissible deviation: ±20 %.
——Oxygen concentration of output gas:21%~100%
——Ventilator compliance: ≤30 Ml/kPa
——Controlled ventilation (IPPV) frequency range: 0 ~ 99times/min, permissible deviation: ±15 %.
——I:E ratio: 4:1~1:4
——Maximum safety pressure: ≤6.0 KPa
——Oxygen consumption: the variation in the gas pressure in the cylinder should be less than or equal
to 1.5MPa/h when the ventilator operates on a 12250KPa / 40L medical oxygen cylinder continuously for one hour.
——Ptr: -0.4 ~ 1.0 KPa, permissible deviation: ±0.15 KPa
——Time to switch between controlled and assisted ventilation modes: 6s, permissible deviation: +1 s, -2 s.
——IMV frequency range: 1 ~ 12 times/min, permissible deviation: ±15%.
——PEEP range: no less than 0.1 ~ 1.0kPa.
——Sigh (deep breath): the inspiration time should be no less than 1.5 times of the original setting.
——Duration of end expiration plateau: 0.1~1.0s,
——Pressure limit range: 1.0~6.0kPa, permissible deviation: ±20 %
——The presentation of the spontaneous breathing frequency, overall respiratory rate and ventilation capacity
is refreshed once every minute.
——Continuous operation duration: the ventilator can operate continuously on a 24-hour basis on an AC utility main.
——Main unit net weight: 15kg, dimension (L*W*H): 390*320*310 (mm).