Gravity Pressure Steam Autoclave with Rectangular Sterilization MDLTA18
High-performance gravity displacement steam sterilization for hospitals, laboratories, and surgical facilities. Available in four configurations with chamber volumes of 0.4–0.5 m³ and single or double-door options.
The MDLTA18 series delivers reliable, validated sterilization cycles with intuitive LCD touch screen controls, robust 15 kW heating, and premium stainless steel 316L construction. Ideal for central sterile processing, research laboratories, surgical instrument reprocessing, and pharmaceutical manufacturing environments.




Clinical Overview
The MDLTA18 series of gravity pressure steam autoclaves represents a breakthrough in sterilization technology, specifically engineered to meet the demanding requirements of modern healthcare facilities, research laboratories, and pharmaceutical manufacturing environments. Utilizing proven gravity displacement sterilization principles combined with advanced automation and precision control systems, the MDLTA18 delivers consistent, reliable sterilization cycles that meet or exceed international standards for medical device reprocessing and laboratory equipment sterilization.
Available in four distinct configurations (MDLTA18A, MDLTA18B, MDLTA18C, and MDLTA18D), this autoclave series offers chamber volumes of 0.4 m³ or 0.5 m³, with single or double-door options to accommodate various facility layouts and workflow requirements. The rectangular chamber design maximizes usable space, allowing for efficient loading of surgical instruments, laboratory glassware, textiles, and other materials requiring steam sterilization. Each unit features an intuitive LCD touch screen interface that simplifies operation while providing comprehensive monitoring and documentation capabilities, ensuring compliance with stringent quality assurance protocols and regulatory requirements.
Key Features & Surgeon Benefits
Rectangular Configuration
- Maximizes usable sterilization space and load capacity
- Accommodates standard instrument trays and large surgical sets efficiently
- Optimized for non-porous items, wrapped instruments, and laboratory equipment
Intuitive Control & Flexibility
- LCD touch screen interface with pre-programmed sterilization cycles
- Single or double-door options for standard or barrier installations
- Rapid heat-up and efficient cycle times increase daily throughput
Long-Term Value
- Premium stainless steel 316L construction ensures durability and longevity
- Service-friendly design minimizes maintenance costs and downtime
- Robust 15 kW heating system reduces cycle time and increases capacity utilization
Four Model Options
- Chamber volumes: 0.4 m³ (MDLTA18A/B) or 0.5 m³ (MDLTA18C/D)
- Door configurations: single-door or pass-through double-door
- Customizable cycle parameters and OEM configurations available
Technical Specifications
| Indications | Medical and laboratory sterilization; surgical instruments, laboratory glassware, textiles, non-porous items, culture media, pharmaceutical equipment |
|---|---|
| Sizes / range | Four models: MDLTA18A (0.4 m³, single door, 121 cm L), MDLTA18B (0.4 m³, double door, 121 cm L), MDLTA18C (0.5 m³, single door, 145 cm L), MDLTA18D (0.5 m³, double door, 145 cm L); all 97 cm W × 175 cm H |
| Material | Chamber: Stainless Steel 316L; construction designed for corrosion resistance and durability |
| Sterilisation | Gravity displacement steam sterilization; temperature range 105–134°C; power supply 380V, 50Hz, 15 kW |
| Packaging | Factory-assembled and tested; includes LCD touch screen control panel, safety interlocks, pressure relief systems, and data logging capabilities |
| Warranty | 2 Year Manufacturer Warranty |
Standard Instrument Composition
| Item | Description | Qty |
|---|---|---|
| Autoclave Unit | Complete MDLTA18 gravity pressure steam autoclave with rectangular stainless steel chamber | 1 |
| LCD Touch Screen Control Panel | Intuitive interface with pre-programmed sterilization cycles and data logging | 1 |
| Door Assembly | Single or double-door configuration depending on model selection | 1 or 2 |
| Safety Interlocks | Pressure-sensitive door locks and thermal monitoring systems | As applicable |
| Pressure Relief Valve | Automatic over-pressurization protection | 1 |
| Drain System | Gravity displacement air removal and condensate drainage | 1 |
| Heating Element | 15 kW power heating system for rapid heat-up and temperature maintenance | 1 |
| Installation Documentation | User manual, technical specifications, maintenance schedule, and compliance documentation | 1 set |
Get in Touch for Pricing & Availability
Contact our sales team to discuss your sterilization requirements, request detailed specifications, arrange a facility demonstration, or obtain pricing for MDLTA18 models and custom configurations.
Email: info@medicaldevicelab.com
Company: Medical Device Lab., Los Angeles, CA







Reviews
There are no reviews yet.